YeeValve is a specialized division of THINKTANK that makes breather valves. We offer free consulting to help people select the right breather valves. Our goal is to help engineering companies save money on projects and help valve distributors understand and select the right breather valves for different applications.
Here are the most simple and fast way to select the right breather valves for your application.
Step 1: Determine the Type of Relief Required
-
Only Pressure Relief: Select the TT7130/8130 series.
-
Only Vacuum Relief: Select the TT7140/8140 series.
-
Both Pressure and Vacuum Relief: Opt for the TT7110/8110 or TT7120/8120 series.
Note: The difference for TT7xxx or TT8xxx series is the TT8xxx outlet size is lager than inlet, and TT7xxx series the inlet is same as outlet. (Very easy, right?)
Please feel free to download our catalog here。
Step 2: Decide the Vent Method (if step 1 already selected TT7130/8130, or TT7140/8140 series, just skip this step.)
-
Direct Vent to Atmosphere: Select the TT7110/8110 series.
-
Vent to Pipeline for Gas Recovery: Select the TT7120/8120 series.
Step 3: Finalize Specifications
-
Set Pressure and Vacuum Value: Confirm the desired pressure and vacuum settings.
-
Material and Size: Choose the appropriate material and valve size.
-
Refer to Set Pressure Charts: Match your specifications with the corresponding model in the set pressure chart.
Examples
Breather valve, Vent to pipeline, 3″, 150LB FF, Set pressure: +250 MMH2O, Set vacuum: -250 MMH2O, A216 WCB
Step 1: see set pressure and vacuum, we select TT7110/8110 or TT7120/8120 series
Step 2: see vent to pipeline, no doubt select TT7120/8120 series.
Step 3: Size check: 3″, Connection check: 150LB FF(if no specific data for outlet, we usually select same size for inlet and outlet.), Set pressure check: +250 MMH2O (kPa=mmH2O×0.00980665, 250mmH2O×0.00980665kPa/mmH2O=2.4516625kPa, so set pressure is 2.45kpa. Set Vacuum check: -250 MMH2O, so the set vacuum is -2.45Kpa.
Let’s see catalog page 6, according to set pressure chart, we know the exactly model is TT7120. (set pressure range 0.2 to 6.9 kpa, and set vacuum range -0.2 to -4.3 kpa. For more details like temperature, Capacity of Tank, Tank Design Vacuum, Fluid, Back Pressure, Flame Arrester Yes/No etc, just double check with our representative。
通气阀与 PRV 泄压阀
我们都知道选择正确的阀门对于确保安全和效率非常重要[...]
八月
通气阀测试程序
在工业储罐系统中,通气阀是确保 [...]
八月
3 个简单步骤即可快速选择合适的呼吸阀
YeeValve 是 THINKTANK 生产呼吸阀的专业部门。我们提供免费咨询 [...]
八月
Service & Technical Support
1. 技术援助 怡阀门为阀门选型、安装和维护提供专家指导。顾客 [...]
可能
订单清单
当您向 Yee Valve 下订单时,您应遵循以下步骤 [...]
可能
如何确定呼吸阀的尺寸?
要正确选择通气阀的尺寸,请按照以下步骤操作: 步骤 1. 确定储罐规格 测量 [...]
可能