In industrial tank systems, the breather valve is a key component to ensure that the pressure and vacuum levels in the tank remain within safe limits. In order to ensure that the YeeValve breather valve works reliably and safely in actual applications, we have a comprehensive testing procedure. In this article, I will show each step of this procedure to ensure that the product works well as expected in actual work.

breather valve visual inspection

Quy trình kiểm tra van thở

1. Kiểm tra trực quan

  • Inspect for Damage: Our QC check the valve body, gaskets, seals, and other components for any visible signs of wear, corrosion, or damage.

  • Check for Debris: Ensure that the valve is clean and free from any impurities that could affect the breather valve's performance.

2. Setup for Test

We have two types of test benches. One is a tank-type operating bench, where the breather valve is installed on the top of tank for actual testing. The other type is a professional breather valve test bench. The breather valve is fixed on a test bench that can simulate actual application operations to test its positive and negative pressure values.

3. Pressure Relief Test

  • Apply Pressure: Gradually increase the pressure in the system to the valve’s set pressure (positive pressure relief).

  • Observe Opening: The valve should open when the applied pressure reaches the set point. Record the pressure at which the valve begins to open.

  • Check for Leakage: Before the set point is reached, ensure there is no leakage through the valve. Minimal leakage (as per the valve’s specifications) is acceptable, but anything beyond the standard should be noted.

  • Release Pressure: Once the valve opens, reduce the pressure and ensure the valve closes properly. Note the pressure at which the valve reseals.

4. Vacuum Relief Test

  • Apply Vacuum: Slowly decrease the pressure (apply vacuum) in the system to the valve’s set vacuum pressure.

  • Observe Opening: The valve should open at the set vacuum point. Record the vacuum pressure at which the valve begins to open.

  • Check for Ingress: Verify that the valve does not allow any ingress (air intake) until the set vacuum pressure is reached.

  • Release Vacuum: Gradually restore the pressure to normal and confirm that the valve closes and reseals properly.

https://www.youtube.com/watch?v=36AXWCAr0Sc

5. Documentation

Record Results

Document all test results, including the set points, leakage rates, and any observations regarding the valve’s performance.

Certification

If the valve passes all tests, issue a test certificate that includes all relevant data, ensuring it meets the required standards.

6. Final Inspection

Final Visual Check

Perform one last visual inspection to ensure all components are properly reassembled, and there are no signs of damage or wear introduced during testing.

Labeling

Verify that all labels, including those indicating valve size, material, connection type, set pressures and vacuum settings are correctly applied and legible. Ensure the valve has the necessary identification tags or nameplates as per standard requirements.

Cleanliness

Ensure the valve is clean and free from any testing residues that could affect performance in its operational environment.

Packaging

If the valve is ready for dispatch, we will pack it securely using appropriate materials to prevent damage during transportation. Include the test certificate and any relevant documentation in the package. (Based on the customer requirements, if customer not allow any paper come with the valves, we will not put the documents)

7. Certification and Documentation

Test Report

We will provide a detailed test report that includes all relevant test results, observations, and confirmations of compliance with applicable standards. This certificate should be signed by our responsible testing engineer.

Tài liệu

Ensure all documentation, including the test report, maintenance logs, and any calibration certificates for the testing equipment, are properly filed and accessible for future reference.

8. Review and Approval

Quality Control Review

Have the testing results reviewed and approved by a quality control engineer or supervisor to ensure all procedures have been followed correctly and the valve meets the required standards.

Customer Notification

Finally, the representative will inform the customer that the valve has passed all required tests and is ready for delivery, and send them with the test report and any other relevant documentation.

Conclusion

Through this series of stringent tests, we make sure that every valve we ship meets both our customers’ requirements and the requirements of the industry. This process not only makes our product more reliable, but it also gives our customers peace of mind that their equipment is safe. Finally, with all the documentation and certification procedures we have in place, we provide complete quality assurance for every batch of YeeValve breather valves that leaves our facility.

If you need any further adjustments or additions, feel free to let me know!

Van thở và van giảm áp PRV

Chúng ta đều biết việc lựa chọn loại van phù hợp là quan trọng để đảm bảo an toàn và hiệu quả cho [...]

Quy trình kiểm tra van thở

Trong hệ thống bồn chứa công nghiệp, van thở là bộ phận quan trọng đảm bảo cho […]

3 bước đơn giản để nhanh chóng chọn đúng van thở

YeeValve là một bộ phận chuyên biệt của THINKTANK sản xuất van thở. Chúng tôi cung cấp dịch vụ tư vấn miễn phí […]

Service & Technical Support

1. Hỗ trợ kỹ thuật Yee Valve cung cấp hướng dẫn chuyên môn về việc lựa chọn, lắp đặt và bảo trì van. Khách hàng […]

Danh sách kiểm tra đơn hàng

Khi bạn đặt hàng với Yee Valve, đây là các bước bạn nên làm theo [...]

Làm thế nào để định cỡ van thở?

Để xác định kích thước chính xác của van thở, hãy làm theo các bước sau: Bước 1. Xác định thông số kỹ thuật của bể Đo [...]